The 3 FDA medical device classes: differences and examples explained

     

    There are distinct FDA medical device classes for a reason. If you're getting a replacement heart valve, you probably want to know the device going into your chest went through a more rigorous approval process than a pair of surgical tweezers. Thankfully, the FDA agrees with you.

    As you plan a route to market for your medical device, it's important you understand early what each class means, which class your device falls into, and what your regulatory pathway looks like as a result.

    We've broken down all of the medical device classes in detail to help you understand them all.

     

    Table of Contents

    1. What are FDA medical device classes?
    2. Medical devices examples
    3. Differences between FDA medical device classes
    4. What is an FDA Class I medical device?
      1. Class I medical device examples
      2. Bringing a Class I medical device to market
    5. What is an FDA Class II medical device?
      1. Class II medical device examples
      2. Bringing a Class II medical device to market
    6. What is an FDA Class III medical device?
      1. Class III medical device examples
      2. Bringing a Class III medical device to market
    7. How to classify medical devices
    8. Accelerate your route to market with the right tools

     

     

    What are FDA medical device classes?

     

    The FDA regulates all medical devices marketed in the U.S. and assigns every single one a 'class' based on its risk profile: that is, the potential threat posed to the safety and health of a patient were something to go wrong with it.

    How many medical device classes are there?

    Any medical device approved by the FDA Center for Devices and Radiological Health is classified into one of three classes: either Class I, II or III, depending on its risk, invasiveness and potential impact on patient health.

    Class I represents devices with the lowest risk profile, while Class III devices pose the highest risk.

    But where are the lines drawn between each of these three classes, and why?

    There's an enormous difference in the optimal paths to market, depending on how your device is grouped. Class I devices, obviously and logically, are subject to far fewer regulatory requirements than Class II or III devices.

     

    Download medical device classification PDF guide

     

     

    Medical devices examples

     

    To bring this distinction to life, let's take a quick look at the types of medical devices that fall into each risk category.

     

    Medical device classes

     

    These medical device examples help bring the class hierarchy into focus.

    We can see that the low-risk devices with minimal patient impact, like bandages and toothbrushes, fall into Class I on our medical device list.

    Examples of medical devices with a high-risk category include highly invasive and life-critical applications like ventilators, while medium-risk devices like syringes and insulin pumps fall into the middle category of Class II.

     

    Differences between FDA medical device classes

     

    Before we get into classes and their differences, we need to understand specialties.

    The FDA has classified over 1,700 distinct types of medical devices, organized in the Code of Federal Regulations (CFR) according to 16 grouping 'specialties'. Classifying your device according to one of these specialties is the first step to understanding whether you are manufacturing a Class I, II or III medical device.

    The 16 specialties are:

    • Anesthesiology
    • Cardiovascular
    • Chemistry
    • Dental
    • Ear, nose and throat
    • Gastroenterology and urology
    • General and plastic surgery
    • General hospital
    • Hematology
    • Immunology
    • Microbiology
    • Neurology
    • Obstetrical and gynecological
    • Ophthalmic
    • Orthopedic
    • Pathology
    • Physical medicine
    • Radiology
    • Toxicology

     

    After finding your specialty, it's time to move into classes.

    As we'll see, the class you sit in determines your regulatory pathway and the level of oversight the FDA requires.

    For example, Class I devices, and a handful of exempt Class II devices, are exempt from premarket notification and approval processes, while Class III and the majority of Class II devices require active dialog with and investigation by the FDA.

    Another type of device may be exempt from some regulatory controls, depending on its intended use. A humanitarian device exemption may be issued for devices intended to help with rare diseases, as the sample size is often too small to obtain enough clinical evidence to meet the FDA’s reasonable assurance standards for 'safety and effectiveness' laid out in Sections 514 and 515 of the Federal Food, Drug and Cosmetic Act.

    However, all devices regulated by the FDA are subject to current Good Manufacturing Practice (cGMP) requirements for registration, labeling and quality.

    So, with those caveats in mind, how do you know if your device is Class I, II or III, and whether or not you’re required to undergo premarket notification?

    Let's take a look at each class in turn.

     

    What is an FDA Class I medical device?

     

    The FDA defines Class I devices as:

     

    "not intended for use in supporting or sustaining life or of substantial importance in preventing impairment to human health, and they may not present a potential unreasonable risk of illness or injury."

     

    These devices are the most common class of devices regulated by the FDA, constituting 47% of approved devices on the market.

    Class I devices have minimal contact with patients and low impact on a patient's overall health. In general, Class I devices do not come into contact with a patient's internal organs, central nervous system or cardiovascular system.

    These devices are subject to the fewest regulatory requirements.

     

    Class I medical device examples

     

    • Electric toothbrush
    • Tongue depressor
    • Oxygen mask
    • Reusable surgical scalpel
    • Bandages
    • Hospital beds
    • Non-electric wheelchair

     

    Bringing Class I medical devices to market

     

    As you might expect, Class I devices are the fastest and easiest to bring to market since they present the lowest amount of risk to the patient and are rarely critical to life-sustaining care. The majority of Class I devices are exempt from FDA requirements for Premarket Notification (510(k)) and Premarket Approval (PMA).

    Class I devices are not exempt from FDA General Controls, a series of commands which applies to Class I, II and III medical devices. The provisions of General Controls address adulteration, misbranding, device registration, records and good manufacturing practices.

    Medical device manufacturers who fall into Class I are still required to implement a quality management system and follow standards to ensure a quality product.

     

    What is an FDA Class II medical device?

     

    Class II medical devices are more complicated than Class I devices and present a higher category of risk because they are more likely to come into sustained contact with a patient. This can include devices which come into contact with a patient's cardiovascular system or internal organs, and diagnostic tools.

    The FDA defines Class II devices as:

     

    devices for which general controls are insufficient to provide reasonable assurance of the safety and effectiveness of the device.

     

    Class II medical device examples


     

    • Catheters
    • Blood pressure cuffs
    • Pregnancy test kits
    • Syringes
    • Blood transfusion kits
    • Contact lenses
    • Surgical gloves
    • Absorbable sutures

     

    Bringing Class II medical devices to market

     

    Controls vary depending on the device, but according to the FDA, can include:

    • Device performance
    • Post-market surveillance
    • Patient registries
    • Special labeling requirements
    • Premarket data requirements
    • Guidelines

     

    Class II devices are subject to the same General Controls mentioned above, as well as Special Controls. These regulations depend on the device and may include special labeling requirements, patient registries and performance standards.

     

    RELATED READING: 4 major Class II medical device requirements

     

    Most importantly, most Class II devices come to market using the premarket notification 510(k) process. The 510(k) is a complex application to the FDA, which demonstrates that a device is safe and effective by demonstrating that the device is equivalent to another device which is on the market.

    This process involves showing 'substantial equivalence' to the existing marketed device, known in FDA parlance as the 'predicate'. This doesn't mean the devices need to be identical, but they require significant similarities in use, design, materials, labeling, standards and other characteristics.

    The FDA released an exemption list in early 2018 which exempts over 800 device types from the 510(k) process. If you have a generic Class II medical device, you can discover whether it is exempt from a 510(k) filing by reading our guide.

    Because a 510(k) could theoretically be completed for any device class within certain parameters, we built this handy decision tree map to help you determine if you need one:

    3 medical device classes FDA 510(k)

     

    Download 510(k) submission checklist

     

     

    What is an FDA Class III medical device?

     

    The FDA defines Class III devices as products which:

     

    “usually sustain or support life, are implanted or present a potential unreasonable risk of illness or injury."

     

    Just 10% of the devices regulated by the US FDA fall into Class III. This classification is generally extended to permanent implants, smart medical devices and life support systems.

     

    Class III medical device examples

     

    • Breast implants
    • Pacemakers
    • Defibrillators
    • High-frequency ventilators
    • Cochlear implants
    • Fetal blood sampling monitors
    • Implanted prosthetics

     

    Bringing Class III medical devices to market

     

    Class III devices are subject to all General Controls and the FDA's Premarket Approval (PMA) process. The FDA writes that 'general and special controls alone are insufficient to assure the safety and effectiveness of Class III devices'.

     

    Read how a Class III manufacturer built a world class quality management system for long-term compliance

     

    Appropriately, the PMA is the most intensive type of device marketing application required by the FDA.

    As you can see in our decision tree above, some FDA Class III devices may qualify for the 510(k) route if you can find a suitable predicate marketed before the Medical Device Amendments of 1976. But as time goes by, this pathway is getting more and more unlikely and rare, since the FDA frowns on the use of predicates any older than a decade. The PMA is therefore by far your most likely option for a Class III device.

    The PMA process and premarket review require a rigorous study of your Class III medical device to prove safety and effectiveness through the development of a data-driven benefit/risk profile.

    The PMA process generally involves clinical trials, and significant time and resources for sufficient data collection. The FDA will also perform a substantive review of your quality system during this time. 

     

    RELATED READING: The difference between premarket notification 510(k) and premarket approval

     

     

    How to classify medical devices

     

    The first step towards classifying your medical device is to navigate the FDA classification regulations, the list of 16 categories for medical devices according to medical specialization.

    As an example, we'll show you the steps to identify the classification of a blood pressure alarm. The device is classified under Category 870: cardiovascular devices.

     

    FDA Class 1

     

     

    Once you've located the relevant medical specialty, click on the category, and navigate the list of devices until you find an equivalent and the associated device code.

     

    FDA Clas 2

     

     

    Click on the device code and open the guidelines. The device classification is listed under section (b). In this case, we can see that we're dealing with a Class II medium-risk device.

     

    FDA Class 3

     

    If your device lacks a listed equivalent among the 1,700 devices classified by the FDA, it is most likely an innovative device without a substantial equivalent, putting you in  Class III territory.

     

     

    Accelerate your route to market with the right tools

     

    Complex FDA clearance processes like the 510(k) or premarket approval demand vast amounts of device data and demonstrable proof of an airtight, high-performing quality management system.

    Legacy quality management tools like paper and spreadsheets clutter, complicate and slow down your premarket processes and make clearance more difficult.

    Whatever your medical device class, consider investing in a dedicated electronic quality management system (eQMS). Modern eQMS tools like Qualio centralize your device data and automate key quality processes, accelerating FDA compliance readiness by months

    Book a demo to see how it works!